Neuroimaging Software

FreeSurfer recon-all: an overview

FreeSurfer reconstructs the brain’s cortical surfaces from a T1-weighted MRI and measures things such as cortical thickness, surface area and the volumes of subcortical structures. Its main command, recon-all, runs a long automated pipeline. This article explains what it does and how to use it responsibly.

Learning objectives

  • Describe what recon-all produces.
  • Explain why surface-based analysis differs from voxel-based analysis.
  • Run and organise a basic recon-all job.
  • Know where manual quality control is required.
FreeSurfer pial surface with Desikan-Killiany parcellation
FreeSurfer pial surface with Desikan-Killiany parcellation. Image: Craiginlimbo, CC BY-SA 4.0, via Wikimedia Commons (File:Jt_rh_pial_freesurfer_tksurfer2.png).

What recon-all does

In outline, recon-all removes the skull, corrects intensity inhomogeneity, segments white matter and subcortical structures, builds a surface at the gray-white boundary and another at the pial surface, and then measures thickness as the distance between them. It also inflates and registers the surfaces to a common spherical atlas so that results can be compared between people.

Why surfaces?

The cortex is a folded sheet. Surface-based methods respect that geometry, so measures like thickness are sampled along the cortex rather than blurred across neighbouring folds, as can happen with voxel-based smoothing.

Running it

# Illustrative. Check the documentation for your FreeSurfer version.
export SUBJECTS_DIR=$HOME/freesurfer_subjects
recon-all -s sub-01 -i sub-01_T1w.nii.gz -all

Expect a run of several hours per subject. Jobs are usually launched in parallel on a cluster or a multi-core workstation.

Outputs to know

FolderContents
mri/Volumes: segmentations, brain masks, normalised T1
surf/Surface files such as white and pial surfaces
label/Cortical parcellations
stats/Summary measures such as thickness and volume tables

Quality control

Automated reconstruction can fail quietly. Common problems include errors in the skull strip, surfaces that cross into dura or vessels, and misplaced white-matter boundaries in images with motion or poor contrast. Inspect every subject, and correct or exclude problem cases according to a written protocol decided before the analysis.

Key takeaways

  • recon-all builds cortical surfaces and measures thickness, area and volumes.
  • Surface analysis follows the folded geometry of the cortex.
  • Runs take hours; plan computing accordingly.
  • Visual quality control is essential.

SpinLab can generate a complete script for workflows like this from the steps you choose.

Frequently asked questions

Can recon-all run on any MRI?

It is designed for T1-weighted images of good quality. Other contrasts and very low resolution may need different handling.

Is the result a real measurement?

Cortical thickness estimates depend on image quality and software version, so compare only data processed the same way.

References and further reading

  • Fischl B. FreeSurfer. NeuroImage. 2012;62:774-781.
  • Dale AM, Fischl B, Sereno MI. Cortical surface-based analysis. I. Segmentation and surface reconstruction. NeuroImage. 1999;9:179-194.
  • FreeSurfer documentation: surfer.nmr.mgh.harvard.edu

Related articles

Last reviewed: 4 November 2026. Educational overview. Commands are illustrative: options change between versions, so check the official documentation for the version you install. Do not process identifiable patient data outside approved systems.