MRI Brain Anatomy: Imaging Planes and What You See
Learning objectives
- Name the three standard imaging planes and what each shows best
- Apply the radiological display convention
- Recognise grey matter, white matter and CSF by signal on T1 and T2



Example brain MRI in three planes. Images: 511KeV, CC BY-SA 4.0, via Wikimedia Commons. Slices come from one example series; they are shown for orientation and are not a diagnostic set.
The three standard planes
| Plane | Divides the body into | Good for |
|---|---|---|
| Axial (transverse) | Upper and lower | Overview of the brain, ventricles, lesions in the hemispheres |
| Coronal | Front and back | Hippocampi, temporal lobes, pituitary, brainstem width |
| Sagittal | Left and right | Midline structures: corpus callosum, cerebellar vermis, pituitary |
Display convention
Axial and coronal images are conventionally displayed as if viewed from the feet or from the front, so the patient’s right appears on the left of the image. Always check the orientation markers or header rather than assuming, because research software may use other conventions (for example neurological convention).
Tissue contrast at a glance
| Tissue | T1-weighted | T2-weighted |
|---|---|---|
| Grey matter | Intermediate to darker | Intermediate to brighter |
| White matter | Brighter | Darker |
| CSF | Dark | Very bright |
This is the typical pattern in adults at common clinical field strengths. Contrast is influenced by sequence and parameters; see T1 and T2 relaxation for the physics behind it.
Structures worth learning first
- Lateral ventricles and the third and fourth ventricles
- Corpus callosum (best seen on mid-sagittal images)
- Basal ganglia and thalami (axial)
- Hippocampi (coronal, temporal horn level)
- Cerebellum and brainstem (sagittal)
Key takeaways
- Choose the plane that answers the question; most protocols acquire at least two
- Know your display convention before interpreting left and right
- Learn normal first: pathology is recognised as a departure from it
FAQ
Why do protocols acquire more than one plane?
A structure can be partially volume-averaged in one plane and clear in another, so multiple planes increase confidence.
Can software reformat a 3D scan into any plane?
Yes, if the acquisition is isotropic or near-isotropic, such as a 3D T1 sequence. Reformats of thick-slice 2D data are less detailed.
Learning more
- Brown RW, Cheng YCN, Haacke EM, Thompson MR, Venkatesan R. Magnetic Resonance Imaging: Physical Principles and Sequence Design, 2nd ed. Wiley; 2014.
- ISMRM educational resources (ismrm.org).
Educational disclaimer: this article is for learning. Parameters and appearances described are illustrative and vary by scanner, field strength, vendor and protocol. It is not medical advice and does not replace local protocols or clinical judgement.