MRI PlanningSpine Planning

MRI Cervical Spine: Protocol, Positioning and Planning

This guide covers a routine cervical spine MRI from start to finish: anatomy and landmarks, indications, safety and preparation, positioning from coil to first image, and each sequence with its planning image and example parameters.

Anatomy and planning landmarks

The cervical spine has seven vertebrae (C1–C7) and the intervertebral discs from C2–C3 to C7–T1. C1 (atlas) has no vertebral body, and C2 (axis) carries the dens. The spinal cord lies in the canal, surrounded by bright CSF on T2, and the nerve roots leave through the neural foramina, which point obliquely forwards at about 45°.

For counting levels, the dens of C2 and the large C2 body are the most reliable landmarks on the sagittal images. The cervical spine is normally lordotic (curved forwards), so each disc has a different angle and axial blocks are angled one disc at a time.

Indications

  • Neck pain with arm pain (radiculopathy) or signs of myelopathy
  • Degenerative disease: disc herniation, canal and foraminal stenosis
  • Suspected cord lesions: demyelination, myelitis, tumour, syrinx
  • Infection (discitis, epidural abscess) and tumour or metastases
  • Trauma with suspected ligament, cord or disc injury (according to local trauma pathway)

Safety screening

Every patient completes standard MRI safety screening before entering the scanner room, and any implant or device is checked against its MR Conditional labelling for your scanner. Ask specifically about spinal fixation, neurostimulators and previous neck surgery. See MRI implant and device screening for the full process.

Patient preparation

  • Remove necklaces, earrings, hair accessories, hearing aids and dentures with metal
  • Explain the importance of not swallowing or moving during each sequence; swallowing causes artefact across the cord
  • Give earplugs or headphones and the call bell
  • Check whether contrast is requested (tumour, infection, post-operative) and complete renal and allergy screening
  • Record the patient’s weight for SAR calculation

Positioning

StepTypical approach
PositionSupine, head first
CoilHead–neck coil, or dedicated neck/spine array
AlignmentHead straight, chin slightly tucked to reduce lordosis; shoulders down
CentringLaser at the level of the thyroid cartilage (about C4–C5) or the chin–hyoid region
ImmobilisationPads either side of the head and under the neck curve; knee support

Step by step: from coil to first image

  1. Check the request and screening: identity, indication, contrast needs and completed MRI safety screening.
  2. Prepare the head–neck coil and place a pad to support the neck curve.
  3. Lay the patient supine, head first, with the head and neck in the posterior coil and the shoulders as low as they comfortably go.
  4. Straighten the head and neck along the table; tuck the chin slightly to reduce the lordosis.
  5. Pad both sides of the head and support the knees.
  6. Attach the anterior neck coil and lock it; check that it does not press on the throat.
  7. Give the call bell and earplugs or headphones, and explain the instruction not to swallow during scans.
  8. Switch on the laser and landmark at about the thyroid cartilage, then move the table to isocentre.
  9. Register the patient on the console and check that the coil elements are detected.
  10. Run the three-plane localiser and check that C1 to T1 are covered and that the neck is straight on the coronal image.

General photos of MRI equipment and workflow; your scanner, coils and room will look different. Images via Wikimedia Commons (credits in each image’s media details).

Cervical spine MRI protocol and planning

The sequences below make up a typical examination. Sequence names differ between vendors (for example TSE/FSE, HASTE/SSFSE, SPACE/CUBE/VISTA). All parameters are illustrative examples, mostly for 1.5 T, and must be adapted to your scanner, coil and local protocol.

1. Three-plane localiser

Planning: Acquire a localiser in three planes. Check that the whole cervical spine, from the skull base to T1, is covered, and that the spine is straight on the coronal image.

2. Sagittal T2 TSE

Cervical spine MRI sagittal slice planning on an axial image
Sagittal slices planned parallel to the midline on an axial image, covering the neural foramina on both sides. Sagittal T2: Nevit Dilmen, CC BY-SA 3.0 (T2 channel shown in grey scale); axial T2: Hellerhoff, CC BY-SA 4.0 (case of cervical myelopathy); via Wikimedia Commons. Planning lines added by MRISpin for illustration.

Planning: Plan on the axial (and coronal) localiser, parallel to the midline of the spinal cord. Cover from one neural foramen to the other, at least the width of the vertebral bodies with the foramina. Cover from the skull base to T1–T2 in the craniocaudal direction. Place an anterior saturation band over the throat to reduce swallowing and flow artefact.

ParameterExample value (illustrative)
Slice thickness / gap3 mm / 10%
TR / TEabout 3000–4000 ms / 100–120 ms
Field of view240–260 mm
Matrix384 × 300 or similar
Phase directionHead–feet (with oversampling) to keep swallowing artefact off the cord

3. Sagittal T1 TSE

Planning: Copy the sagittal T2 geometry.

ParameterExample value (illustrative)
Slice thickness / gap3 mm / 10%
TR / TEabout 500–700 ms / 10–15 ms
Field of view240–260 mm

4. Sagittal STIR (if requested)

Planning: Copy the sagittal geometry. STIR is useful for bone marrow oedema, trauma, infection and cord lesions.

ParameterExample value (illustrative)
Slice thickness3 mm
TIabout 150 ms at 1.5 T
TR / TEabout 3500 ms / 40–60 ms

5. Axial T2 (or T2* gradient echo)

Cervical spine MRI axial slice planning with blocks parallel to each disc
Axial blocks planned on the sagittal T2 image, each angled parallel to its intervertebral disc. Sagittal T2: Nevit Dilmen, CC BY-SA 3.0 (T2 channel shown in grey scale); axial T2: Hellerhoff, CC BY-SA 4.0 (case of cervical myelopathy); via Wikimedia Commons. Planning lines added by MRISpin for illustration.

Planning: Plan on the sagittal T2. Place a block of 3–4 slices through each disc from C2–C3 to C7–T1, each block angled parallel to its disc. Check on the coronal image that the slices are straight across the spine. As an alternative, a continuous stack from C2 to T1 can be used for cord lesions. T2* gradient echo gives good contrast between grey matter, white matter and CSF in the cervical cord.

ParameterExample value (illustrative)
Slice thickness / gap3 mm / 10%
TR / TEabout 3000–4500 ms / 100 ms (TSE) or 2D/3D T2* GRE
Field of view160–180 mm
Matrix256 × 256 or similar

6. Post-contrast T1 (if requested)

Planning: Repeat sagittal and axial T1 after gadolinium, with fat suppression where available, using the same geometry as the pre-contrast images.

Tips and common pitfalls

  • Swallowing is the main artefact in the cervical spine; give clear instructions and use an anterior saturation band.
  • Count levels from C2 on the sagittal images and check the level against the axial slices.
  • The cord should be in the centre of the sagittal block; rotate the block on the axial image if the neck is rotated.
  • CSF flow artefact can mimic lesions on T2; check on a second sequence or plane.
  • Large shoulders can lower signal at C7–T1; pull the shoulders down gently and check coil coverage.

Frequently asked questions

Why angle each axial block separately?

Because of the cervical lordosis, the discs are at different angles. Angling each block to its disc gives true cross-sections of the disc, canal and foramina.

When is the whole spine scanned?

For suspected multiple sclerosis, metastases, or symptoms that do not localise to one region, follow the dedicated whole-spine or neurological protocol.

References and further reading

  • Westbrook C. Handbook of MRI Technique. 4th ed. Wiley-Blackwell; 2014.
  • Westbrook C, Talbot J. MRI in Practice. 5th ed. Wiley-Blackwell; 2018.
  • Möller TB, Reif E. Pocket Atlas of Sectional Anatomy, Volume III: Spine, Extremities, Joints. Thieme.

Related articles

Last reviewed: 6 November 2026. Educational content only. Positioning, coverage, sequences and parameters are illustrative examples. Always follow your department protocol, the referral question, MRI safety screening and the vendor recommendations for your scanner and coils.

MRISpin Team

MRISpin team combines decades of experience in MRI research, clinical practice, and science communication. Meet the people driving MRISpin’s mission.

Related Articles

Back to top button