MRI ProtocolsNeuro

Dementia MRI protocol: atrophy, small vessel disease, microbleeds and ARIA

Learning objectives

  • Build a dementia MRI protocol around 3D T1, FLAIR, SWI and DWI
  • Assess medial temporal lobe atrophy with a visual rating scale
  • Know why SWI matters for microbleeds and anti-amyloid treatment
  • Recognise patterns that suggest other causes, such as normal pressure hydrocephalus
Coronal MRI comparing medial temporal lobe atrophy in Alzheimer disease, dementia with Lewy bodies and a control
Medial temporal lobe atrophy, especially of the hippocampus, is more marked in Alzheimer disease than in dementia with Lewy bodies, compared with a normal control. Image: McKeith IG et al., edited by Lukelahood, CC BY 4.0, via Wikimedia Commons.

What MRI adds in cognitive decline

MRI in memory clinics has two jobs: to exclude treatable or alternative causes (tumour, subdural haematoma, normal pressure hydrocephalus, vascular disease) and to look for patterns of atrophy that support a diagnosis, such as hippocampal atrophy in Alzheimer disease. With anti-amyloid antibody treatments now in use in some countries, MRI is also needed before and during treatment to monitor amyloid-related imaging abnormalities (ARIA).

Example protocol

SequencePlanePurpose
3D T1-weighted (e.g. MPRAGE), about 1 mm isotropicSagittal acquisition, coronal reformatsAtrophy pattern, hippocampal volume, volumetry
FLAIR (2D axial or 3D)AxialWhite matter hyperintensities (small vessel disease), infarcts, ARIA-E (oedema)
SWI or T2* gradient echoAxialMicrobleeds, superficial siderosis, ARIA-H
DWIAxialAcute infarcts, Creutzfeldt–Jakob disease
Coronal T2 (optional)Perpendicular to the hippocampusHippocampal detail

Contrast is not routine and is used only when another condition, such as a tumour or inflammation, is suspected.

Rating medial temporal lobe atrophy

On coronal T1 images through the hippocampal body, the Scheltens medial temporal lobe atrophy (MTA) scale scores each side from 0 (no atrophy) to 4 (severe), based on the width of the choroid fissure, the width of the temporal horn and the height of the hippocampus. Some atrophy is normal with age, so scores are interpreted against age-related cut-offs.

Other ratings and findings

  • Fazekas scale for white matter hyperintensities on FLAIR (0–3).
  • Microbleeds on SWI: a lobar pattern suggests cerebral amyloid angiopathy; deep microbleeds suggest hypertensive small vessel disease.
  • Posterior atrophy (precuneus, parietal lobes) in some forms of Alzheimer disease.
  • Frontal and anterior temporal atrophy in frontotemporal dementia.
  • Restricted diffusion in the cortex or basal ganglia in Creutzfeldt–Jakob disease.
Coronal images comparing normal pressure hydrocephalus with brain atrophy
Normal pressure hydrocephalus (left, CT) with tight high-convexity sulci, compared with atrophy (right, MRI), in the coronal plane. Image: Damasceno BP, CC BY 4.0, via Wikimedia Commons.

Normal pressure hydrocephalus

In normal pressure hydrocephalus the ventricles are large out of proportion to the sulci, and on coronal images the sulci at the top of the brain are tight while the Sylvian fissures are wide. Recognising this pattern matters because it may respond to CSF shunting, unlike atrophy.

MRI and anti-amyloid treatment

Appropriate use recommendations for antibodies such as lecanemab call for a baseline MRI with FLAIR, SWI (or T2*) and DWI before treatment, and scheduled MRIs during the first months of treatment to detect ARIA. Patients with many microbleeds or superficial siderosis at baseline may not be suitable for treatment. A consistent protocol on the same scanner makes comparison easier.

References

  • Scheltens P, Leys D, Barkhof F, et al. Atrophy of medial temporal lobes on MRI in “probable” Alzheimer’s disease and normal ageing: diagnostic value and neuropsychological correlates. J Neurol Neurosurg Psychiatry 1992;55(10):967–972.
  • Cummings J, Apostolova L, Rabinovici GD, et al. Lecanemab: appropriate use recommendations. J Prev Alzheimers Dis 2023;10(3):362–377.

Related articles

Last reviewed: 7 November 2026. Protocols and parameters are illustrative examples. Local protocols, scanner software, radiologist preference and manufacturer guidance take priority. MRI safety screening applies to every patient.