Circle of Willis on MRI: brain artery anatomy and time-of-flight MRA
Learning objectives
- Name the vessels that form the circle of Willis and the main branches seen on brain MRA
- Recognise common normal variants
- Explain how time-of-flight (TOF) MRA creates bright vessels without contrast
- Know the pitfalls that can mimic or exaggerate disease


The circle of Willis
The circle of Willis is a ring of arteries at the base of the brain that connects the anterior (carotid) and posterior (vertebrobasilar) circulations. When it is complete, it can provide collateral flow if one feeding artery is narrowed or blocked.
| Part of the circle | Comes from | Supplies (mainly) |
|---|---|---|
| Internal carotid arteries (terminal parts) | Common carotid arteries | Anterior circulation |
| A1 segments of the anterior cerebral arteries | Internal carotid arteries | Medial frontal and parietal lobes (via the ACAs) |
| Anterior communicating artery | Connects the two A1 segments | Links the left and right anterior circulation |
| Posterior communicating arteries | Internal carotid arteries | Link anterior and posterior circulation |
| P1 segments of the posterior cerebral arteries | Basilar artery tip | Occipital lobes, thalami and midbrain (via the PCAs) |
The middle cerebral artery is not part of the ring, but it is the largest branch of the internal carotid artery and is always assessed on MRA. Its segments are usually described as M1 (horizontal) to M4 (cortical). The anterior and posterior cerebral arteries are described in the same way, from A1 and P1 near the circle outwards.
Normal variants are common
A complete, symmetrical circle is the exception rather than the rule. In a 3D TOF MRA study of healthy adults, Krabbe-Hartkamp and colleagues found a complete circle in fewer than half of the participants. Common variants include:
- Hypoplastic (thin) or absent posterior communicating artery on one or both sides
- “Fetal” origin of the posterior cerebral artery, where the PCA is supplied mainly from the internal carotid artery through a large posterior communicating artery
- Hypoplastic or absent A1 segment, with both anterior cerebral arteries filled from one side
- Duplicated or fenestrated segments, especially of the anterior communicating artery and the basilar artery
These variants matter in stroke because they change which territory a blocked artery supplies, and in aneurysm assessment because aneurysms are frequent at branch points of the circle.
How time-of-flight MRA works
TOF MRA uses a gradient-echo sequence with a short TR. Stationary tissue inside the imaging slab is repeatedly excited and becomes saturated, so it gives little signal. Blood flowing into the slab has not been excited yet, so it arrives with full magnetisation and appears bright. This is called inflow or flow-related enhancement. A saturation band is placed above the slab to suppress signal from veins flowing in the opposite direction.
The thin source slices are then combined into a maximum intensity projection (MIP), which shows the brightest voxel along each projection line. MIPs are easy to read, but they can hide small details, so the source images should always be reviewed as well.
| TOF parameter | Typical choice (illustrative) | Why |
|---|---|---|
| Acquisition | 3D, several overlapping slabs | Thin slices with good inflow at the edges of each slab |
| TR / flip angle | Short TR with a moderate flip angle | Balance background suppression and vessel signal |
| Echo time | As short as possible | Reduce signal loss from turbulent flow |
| Saturation band | Above the slab | Suppress venous signal |
| Coverage | From below the circle of Willis to above the MCA branches | Include the full circle and proximal branches |
Settings are illustrative and vary with vendor and field strength. TOF works better at 3 T because of higher SNR and longer T1 of background tissue.

Pitfalls
- Slow or turbulent flow loses signal and can make a stenosis look worse than it is, or mimic an occlusion.
- In-plane flow: vessels running within the slab become saturated and fade, for example in tortuous segments.
- Short-T1 material such as subacute haemorrhage (methaemoglobin) or fat can look bright and mimic flow on a MIP.
- Metal and susceptibility (clips, coils, stents, dental work) can cause signal voids near the vessel.
- Very small aneurysms may be hidden on MIPs and are best seen on the source images or reformats.
Frequently asked questions
Does TOF MRA need contrast?
No. It relies on inflow of blood. Contrast-enhanced MRA is used for other indications, such as the neck arteries or when slow flow limits TOF.
Why does one posterior cerebral artery look larger than the other?
Asymmetry is very common and is often due to a fetal-type posterior cerebral artery or a hypoplastic P1 segment, not disease.
References and further reading
- Krabbe-Hartkamp MJ, van der Grond J, de Leeuw FE, et al. Circle of Willis: morphologic variation on three-dimensional time-of-flight MR angiograms. Radiology 1998;207(1):103–111. PubMed
- Möller TB, Reif E. Pocket Atlas of Sectional Anatomy, Volume I: Head and Neck. Thieme.
- Mirza S, Gokhale S. Neuroimaging in acute stroke (2016), CC BY 4.0. Source of the MCA stenosis figure, via Wikimedia Commons.
Related articles
Last reviewed: 6 November 2026. Educational content only. Example parameters are illustrative. Images are examples for anatomy teaching and are not a diagnostic set. It does not replace a radiologist’s report.