MRI Protocols
MRI Sequence Cheat Sheet: T1, T2, FLAIR, DWI, SWI and STIR
Learning objectives
- Say what each common sequence is designed to highlight
- Match a clinical question to a sequence family
- Understand why protocols combine several contrasts





Example slices at different levels of one example series, so anatomy is not identical between panels. Images: 511KeV, CC BY-SA 4.0, via Wikimedia Commons.
Cheat sheet
| Sequence | What it emphasises | Typical use | Watch out for |
|---|---|---|---|
| T1 | Anatomy, fat, subacute blood, post-contrast enhancement | Anatomy; before and after gadolinium | Pathology can be subtle |
| T2 | Fluid and many lesions appear bright | General lesion detection | CSF can hide nearby lesions |
| FLAIR | T2 contrast with CSF signal suppressed | Periventricular and cortical lesions | Flow and CSF artefacts |
| DWI / ADC | Restricted water motion | Acute ischaemia, abscess, some tumours | T2 shine-through; ADC map needed |
| SWI / T2* | Susceptibility: blood products, calcium, iron | Microbleeds, haemorrhage, venous structures | Blooming exaggerates size |
| STIR / fat-sat T2 | Fluid and oedema with fat suppressed | Musculoskeletal, orbits, spine | STIR is not specific to contrast type |
How to think about choosing
- Start from the question: anatomy, fluid, blood, diffusion or enhancement
- Add sequences that remove a confounder (fat or CSF suppression)
- Accept a time trade-off: every extra contrast costs scan minutes
For the physics of two foundational contrasts see spin echo vs gradient echo and T1 and T2.
Key takeaways
- No single sequence is best; protocols are combinations
- Suppression sequences (FLAIR, STIR, fat-sat) trade signal for specificity
- Diffusion needs the ADC map for correct interpretation
FAQ
Is FLAIR a T1 or T2 sequence?
It is T2-weighted with an inversion pulse that nulls fluid signal.
Do all scanners name sequences the same way?
No. Vendors use different names for similar techniques, so check the protocol documentation.
References and further reading
- Brown RW, Cheng YCN, Haacke EM, Thompson MR, Venkatesan R. Magnetic Resonance Imaging: Physical Principles and Sequence Design, 2nd ed. Wiley; 2014.
- Haacke EM, Xu Y, Cheng YCN, Reichenbach JR. Susceptibility weighted imaging (SWI). Magn Reson Med 2004;52:612-618.
Educational disclaimer: this article is for learning. Parameters and appearances described are illustrative and vary by scanner, field strength, vendor and protocol. It is not medical advice and does not replace local protocols or clinical judgement.