MRI Lumbar Spine: Protocol, Positioning and Planning
This guide covers a routine lumbar spine MRI from start to finish: anatomy and landmarks, indications, safety and preparation, positioning from coil to first image, and each sequence with its planning image and example parameters.
Anatomy and planning landmarks
The lumbar spine normally has five vertebrae (L1–L5) above the sacrum. The spinal cord usually ends at about L1–L2 as the conus medullaris, and below this the canal contains the nerve roots of the cauda equina. Each nerve root leaves through the neural foramen below the vertebra of the same number (the L4 root exits at L4–L5).
The lumbar lordosis means that the discs are at different angles, and the L5–S1 disc is usually the steepest. Transitional vertebrae (a lumbarised S1 or sacralised L5) are common, so counting levels should be checked from a fixed point, for example by including the lower thoracic spine on the sagittal localiser or counting from C2 on a whole-spine localiser according to local policy.
Indications
- Low back pain with sciatica (radiculopathy) or neurological signs
- Suspected cauda equina syndrome (urgent, according to local pathway)
- Degenerative disease: disc herniation, canal and foraminal stenosis, spondylolisthesis
- Infection (discitis, epidural abscess), tumour or metastases
- Post-operative assessment
Safety screening
Every patient completes standard MRI safety screening before entering the scanner room, and any implant or device is checked against its MR Conditional labelling for your scanner. Ask specifically about spinal fixation, spinal cord stimulators and intrathecal pumps. See MRI implant and device screening for the full process.
Patient preparation
- Remove all metal, including belts and clothing with metal fasteners, and change into a gown
- Ask about pain; a comfortable patient lies still, so offer support under the knees
- Give earplugs or headphones and the call bell
- Check whether contrast is requested (post-operative, infection, tumour) and complete renal and allergy screening
- Record the patient’s weight for SAR calculation
Positioning
| Step | Typical approach |
|---|---|
| Position | Supine, head first (or feet first according to local practice) |
| Coil | Spine array in the table, with an anterior body array if needed |
| Alignment | Spine straight along the table; arms by the sides or on the chest |
| Centring | Laser about 3–4 cm above the iliac crests (around L3), or at the lower costal margin for higher coverage |
| Immobilisation | Wedge under the knees to flatten the lumbar curve and reduce discomfort |
Step by step: from coil to first image
- Check the request and screening: identity, indication, contrast needs and completed MRI safety screening.
- Prepare the table: check the spine coil elements, place a sheet and a knee wedge.
- Lay the patient supine with the spine straight along the centre of the table.
- Place the knee wedge to reduce the lordosis and improve comfort; check the patient can stay still for the whole scan.
- Place the anterior body array if your system uses one, and secure it.
- Give the call bell and earplugs or headphones.
- Switch on the laser and landmark about 3–4 cm above the iliac crests, then move the table to isocentre.
- Register the patient on the console and select the spine coil elements.
- Run the three-plane localiser and check that T11–T12 to the sacrum are covered and that the spine is straight on the coronal image.




General photos of MRI equipment and workflow; your scanner, coils and room will look different. Images via Wikimedia Commons (credits in each image’s media details).
Lumbar spine MRI protocol and planning
The sequences below make up a typical examination. Sequence names differ between vendors (for example TSE/FSE, HASTE/SSFSE, SPACE/CUBE/VISTA). All parameters are illustrative examples, mostly for 1.5 T, and must be adapted to your scanner, coil and local protocol.
1. Three-plane localiser
Planning: Acquire a localiser in three planes. Check that the lower thoracic spine, all lumbar levels and the sacrum are included, and that the spine is straight on the coronal image.
2. Sagittal T2 TSE

Planning: Plan on the axial and coronal localisers, parallel to the midline of the spine. Cover from one neural foramen to the other (including the lateral parts of the vertebral bodies). Craniocaudally, cover from T11–T12 to the sacrum, including the conus. Place a saturation band anterior to the vertebral bodies to reduce motion and flow artefact from the abdomen.
| Parameter | Example value (illustrative) |
|---|---|
| Slice thickness / gap | 4 mm / 10% |
| TR / TE | about 3000–4000 ms / 100–120 ms |
| Field of view | 280–320 mm |
| Matrix | 384 × 300 or similar |
| Phase direction | Head–feet with oversampling |
3. Sagittal T1 TSE
Planning: Copy the sagittal T2 geometry. T1 shows bone marrow, fat and the vertebral endplates.
| Parameter | Example value (illustrative) |
|---|---|
| Slice thickness / gap | 4 mm / 10% |
| TR / TE | about 500–700 ms / 10–15 ms |
| Field of view | 280–320 mm |
4. Sagittal STIR (if requested)
Planning: Copy the sagittal geometry. STIR helps with fractures, infection, tumour and Modic type 1 change.
| Parameter | Example value (illustrative) |
|---|---|
| Slice thickness | 4 mm |
| TI | about 150 ms at 1.5 T |
| TR / TE | about 3500–4500 ms / 40–60 ms |
5. Axial T2 through the discs

Planning: Plan on the mid-sagittal T2. Place a block of 3–4 slices through each symptomatic disc, usually L3–L4, L4–L5 and L5–S1, each block angled parallel to its disc and covering from the pedicle above to the pedicle below if needed. Check on the coronal image that the slices are straight across the spine. Some protocols add a continuous axial stack from L3 to S1 instead of separate blocks.
| Parameter | Example value (illustrative) |
|---|---|
| Slice thickness / gap | 4 mm / 10% |
| TR / TE | about 3000–5000 ms / 100–120 ms |
| Field of view | 180–200 mm |
| Matrix | 320 × 256 or similar |
6. Post-contrast T1 (if requested)
Planning: Repeat sagittal and axial T1 after gadolinium, with fat suppression where available, using the same geometry as the pre-contrast images. This is used after surgery to separate scar from recurrent disc, and for infection and tumour.
Optional sequences
- Coronal T2 or STIR for scoliosis, sacroiliac joints or paraspinal lesions
- Axial T1 through the symptomatic levels
- A sagittal localiser of the whole spine for counting levels when anatomy is unusual
Tips and common pitfalls
- Always count levels from a reliable landmark and check the count on the localiser; transitional vertebrae are common.
- A knee wedge makes the patient more comfortable and reduces movement.
- Make the axial blocks match the disc angle exactly at L5–S1; if the angle is very steep, check that the slices still pass through the canal.
- Use an anterior saturation band to reduce bowel and breathing artefact.
- For suspected cauda equina syndrome, follow the urgent pathway and keep the protocol short.
Frequently asked questions
Why angle the axial slices at L5–S1 so steeply?
Because of the lumbosacral angle, the L5–S1 disc is often strongly tilted. Slices parallel to the disc show it in true cross-section.
Is contrast needed for back pain?
Not for a first scan of degenerative disease. It is used after surgery, and for suspected infection or tumour.
References and further reading
- Westbrook C. Handbook of MRI Technique. 4th ed. Wiley-Blackwell; 2014.
- Westbrook C, Talbot J. MRI in Practice. 5th ed. Wiley-Blackwell; 2018.
- Möller TB, Reif E. Pocket Atlas of Sectional Anatomy, Volume III: Spine, Extremities, Joints. Thieme.
- Fardon DF, Williams AL, Dohring EJ, et al. Lumbar disc nomenclature: version 2.0. Spine J 2014;14(11):2525–2545.
Related articles
- Disc herniation on MRI
- MRI thoracic spine positioning and planning
- MRI cervical spine positioning and planning
Last reviewed: 6 November 2026. Educational content only. Positioning, coverage, sequences and parameters are illustrative examples. Always follow your department protocol, the referral question, MRI safety screening and the vendor recommendations for your scanner and coils.